A professional solution provider for industrial energy storage and electric vehicle charging piles
12
+years of experience in ESS
31,600
m²industrial park
25,000
m²manufacturing plant
Yes, installing an EV charger is generally a smart and forward-looking investment. For homeowners, it offers significant convenience, cost savings on fuel, and boosts property value. Businesses benefit by attracting customers and employees, enhancing their brand image as sustainable, and gaining a strategic amenity that future-proofs their operations. While upfront costs exist, especially for commercial fast chargers, strong long-term potential exists due to rising EV adoption and available incentives. Overall, it's a worthwhile investment supporting the energy transition.
For residential users, installing a home charger delivers significant cost savings by leveraging off-peak electricity rates,cutting charging costs by 60–70% vs. peak hours, while eliminating fuel expenses and reducing vehicle maintenance.
For commercial operators, charging stations generate direct revenue through service fees, session charges, and subscriptions, alongside ancillary income from on-screen advertising. Strategic advantages include tax credits, enhanced property value, and sustainability branding.
An EV charging station is infrastructure that supplies electrical power to recharge electric vehicles. It consists of connectors (e.g., CCS, CHAdeMO), power conversion and control systems, safety mechanisms , and often network connectivity for payment and remote monitoring. Stations range from residential wall boxes to public ultra-fast chargers.
The fault name
Door opened
Fault code
118
Number of flashing red lights
14
Troubleshooting and illustration


1. This function is for charging piles with door switch.
2. Close the charging pile door and the fault will be removed.
3. If the above operation fails, replace the micro switch.
The fault name
PEN Fault
Fault code
116
Number of flashing red lights
12
Troubleshooting and illustration

Check whether the inlet line N wire is loose, and fix it if it is loose

2. There should be no voltage between PE and N.
3. If there is a voltage, the null line is charged.
4. Check the incoming line until the voltage is normal.

The fault name
PE Fault
Fault code
115
Number of flashing red lights
11
Troubleshooting and illustration


1.Check whether the PE line is loose and fix it.


2.There should be no voltage between PE and N.
3.If there is voltage, the null line will be charged.
4.Check the incoming line until the voltage is normal.
The fault name
Relay Fault
Fault code
114
Number of flashing red lights
10
Troubleshooting and illustration


1.Check whether the back check signal is loose.


2.Check whether the circuit voltage line of the relay coil is loose.
3.If the contactor does not pull, replace the contactor.
The fault name
Type A Switch Fault
Fault code
113
Number of flashing red lights
9
Troubleshooting and illustration



1.Check Type A Switch connection is reliable.


2.Check whether the connection between the trip and the main board is reliable.


3.put the multimeter tap to the buzzer, test whether the conduction, not conduction is normal.
4.Replace the trip.
© 2024 Shenzhen ATESS Power All Rights Reserved. 粤ICP备2023127387号 by GrowthMan